FLIR (Forward-Looking Infrared) cameras are advanced thermal imaging devices used across various industries, including electrical inspections, mechanical diagnostics, building thermography, and defense applications. These cameras play a crucial role in detecting temperature variations, identifying faults, and ensuring process efficiency.
However, over time, FLIR cameras can experience sensor drift due to environmental exposure, usage, and aging components. This drift can lead to inaccurate thermal readings, potentially compromising safety and operational efficiency. To ensure continued accuracy, compliance, and reliability, regular calibration is essential.
At Prism Calibration, we offer comprehensive FLIR calibration services adhering to ISO 17025 accreditation and NIST-traceable standards. Our expert technicians utilize advanced blackbody calibration sources and precision instruments to restore the accuracy of FLIR cameras, ensuring they meet industry regulations and manufacturer specifications.
FLIR calibration is crucial to maintaining the performance and accuracy of thermal imaging devices. Without proper calibration, temperature readings may become unreliable, leading to incorrect assessments, safety risks, and regulatory non-compliance.
– Accuracy Verification: Ensures that temperature measurements remain precise and consistent.
– Regulatory Compliance: Meets industry standards such as ISO 17025, NIST, ASTM, and IEC.
– Operational Efficiency: Reduces false readings and enhances decision-making in diagnostics.
– Safety Assurance: Minimizes the risk of incorrect thermal assessments in critical applications.
– Extended Equipment Life: Regular calibration helps maintain the performance and longevity of FLIR devices.
– Cost Savings: Prevents unnecessary downtime, incorrect diagnoses, and expensive repairs.
FLIR cameras vary in design, functionality, and application. To ensure optimal performance, different calibration methods are used based on the type of FLIR device and its intended use.
– Radiometric Calibration: Adjusts the camera’s temperature measurement accuracy using blackbody sources.
– Non-Radiometric Calibration: Focuses on image clarity without direct temperature validation.
– Multi-Point Calibration: Ensures accuracy at various temperature ranges for comprehensive reliability.
– Emissivity-Based Calibration: Accounts for different material emissivities for precise thermal readings.
– Ambient Temperature Calibration: Tests camera performance under varying environmental conditions.
– On-Site Calibration: Ideal for industries where transporting FLIR cameras is not feasible.
Our expert team evaluates the specific calibration needs of your FLIR handheld, fixed, or UAV-mounted cameras to ensure optimal accuracy and compliance.
To guarantee precision, compliance, and traceability, Prism Calibration follows globally recognized standards for FLIR calibration.
– ISO 17025: International standard for calibration and testing laboratories.
– NIST Traceability: Calibration results are traceable to the National Institute of Standards and Technology (NIST).
– ASTM E1934: Industry-standard guidelines for evaluating thermal imaging systems.
– IEC 60825: International standards for infrared and laser-based equipment calibration.
– Manufacturer Specifications: Calibration procedures aligned with FLIR system manufacturer requirements.
By complying with these standards, we ensure that your FLIR thermal imaging devices deliver highly accurate and repeatable results.
At Prism Calibration, we provide calibration services across a wide array of industries, ensuring precision, compliance, and operational efficiency. Our services are tailored to meet the specific needs of the following key sectors:
Our systematic and meticulous FLIR calibration process ensures that your thermal imaging devices meet precise accuracy requirements.
Evaluating the camera’s current accuracy and identifying deviations.
Inspecting optical components, thermal sensors, and firmware settings.
Establishing stable temperature reference points using high-precision blackbody sources.
Fine-tuning internal thermal sensors to align with standard reference values.
Adjusting emissivity, reflection, and compensation factors for various surfaces.
Conducting multi-point calibration checks at different temperature ranges.
Validating results using traceable NIST standards.
Ensuring compliance with ISO 17025 and ASTM E1934 calibration standards.
Comparing pre- and post-calibration data to verify improvements.
Providing a detailed calibration certificate, test reports, and documentation.
Attaching calibration labels and stickers with due dates for re-calibration.
Upon completion of the calibration process, Prism Calibration provides comprehensive documentation, ensuring compliance and traceability.
– ISO 17025 Calibration Certificate: Validating the accuracy of your FLIR device.
– Detailed Test Reports: Documenting pre- and post-calibration results for comparison.
– NIST Traceability Statement: Confirming adherence to NIST standards.
– Calibration Labels & Stickers: Indicating the next due date for recalibration.
– Regulatory Compliance Documentation: Ensuring compliance with industry and safety standards.
These documents serve as critical proof of compliance for regulatory audits, quality assurance, and operational reliability.
At Prism Calibration, we offer flexible calibration options to meet your specific needs:
– Onsite calibration: Our onsite calibration service brings our expert technicians directly to your facility, ensuring that large, stationary, or difficult-to-transport equipment is calibrated with minimal disruption to your operations. We bring all necessary tools and reference standards, so you can rely on accurate results at your location.
– In-Lab calibration: For portable instruments or systems that can be easily transported, our in-lab calibration provides an ideal solution. You can send your equipment to our state-of-the-art facility, where we will perform the calibration with precise instruments and controlled conditions. Our lab ensures high-quality, traceable results for a wide range of devices.
Why choose both options?
– Convenience: We understand that every calibration need is unique, so we offer both options to ensure you have a service tailored to your operational needs.
– Accuracy: Whether onsite or in-lab, our expert technicians ensure precise and reliable calibration, so your equipment functions optimally.
– Reduced downtime: Both options are designed to minimize downtime and keep your business running smoothly, with fast turnaround times for all services.
Regular preventive maintenance and calibration are essential to ensure the longevity and accuracy of FLIR thermal imaging systems.
– Scheduled Calibration Services: Periodic verification based on usage and industry requirements.
– Optical Lens Cleaning & Alignment: Ensuring clear and undistorted thermal images.
– Sensor Inspection & Diagnostics: Detecting and resolving sensor-related issues.
– Firmware & Software Updates: Upgrading systems for enhanced performance and compatibility.
– Environmental Stress Testing: Simulating various temperature conditions to ensure stability.
By incorporating preventive maintenance into your operational workflow, you can reduce downtime, improve reliability, and enhance safety compliance.
FLIR cameras should be calibrated annually, but high-usage applications may require more frequent calibration.
An uncalibrated FLIR camera may produce inaccurate temperature readings, leading to incorrect diagnostics, safety risks, and regulatory non-compliance.
Yes, we provide both on-site and laboratory-based FLIR calibration services for maximum convenience.
Standard calibration takes 24-48 hours, with expedited services available upon request.
Yes, all our calibration services are NIST-traceable, ensuring compliance with global standards.
Yes, we calibrate handheld, fixed, UAV-mounted, and industrial FLIR cameras.
FLIR calibration is essential for electrical, mechanical, HVAC, aerospace, and defense industries.
You can contact us via phone, email, or online booking to schedule your calibration service.
Yes, calibration ensures optimal image clarity, temperature accuracy, and reliable data output.
Costs vary based on camera type, calibration method, and service level. Request a customized quote for pricing details.