Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Insulation Tester
(Megohmmeter)
Calibration

NABL-accredited calibration for insulation resistance testers (megohmmeters). 100 V to 10 kV test voltage. 0.1 MΩ to 20 TΩ resistance range. IEC 61557-2. All makes.

0.1 MΩ–20 TΩ

Resistance

100 V–10 kV

Test Voltage

IEC 61557-2

Standard

IEC 61557-2

Insulation Resistance Measurement

Insulation tester megohmmeter calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480IEC 61557-2100 V–10 kVMΩ to TΩDAR & PIHigh VoltageNPL TraceableISO 9001 AcceptedAll GujaratNABL CC-2480IEC 61557-2100 V–10 kVMΩ to TΩDAR & PIHigh VoltageNPL TraceableISO 9001 AcceptedAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS INSULATION TESTER CALIBRATION —

What Is Insulation Tester Calibration & Why Does It Matter?

Think of a quality lab that relies on an insulation tester for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Insulation Tester calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Insulation Testers We Calibrate

Handheld / High-Voltage / DAR-PI / Combo / Transformer / IMD · All Makes · IEC 61557-2 · NABL

01

Megohmmeter (250V/500V/1000V)

Standard megohmmeters for motor, cable, and transformer insulation testing.

250 V / 500 V / 1000 V DCAcc: ±5% FSIEC 61557
02

High Voltage Insulation Tester (2500V/5000V)

High-voltage insulation testers for critical HV equipment and switchgear.

2500 V / 5000 V DCAcc: ±5% FSIEC 61557
03

Hi-Pot / Dielectric Strength Tester

Hi-Pot testers for dielectric strength testing of electrical equipment.

0–10 kV AC/DCAcc: ±5% FSIEC 61010
04

Leakage Current Tester

Leakage current testers for safety compliance of electrical appliances.

0–50 mA ACAcc: ±2% FSIEC 60990
05

Continuity/Bonding Tester

Continuity and bonding testers for earthing and protective conductor testing.

0–200 ΩAcc: ±2% FSIEC 61557
06

Earth Loop Impedance Tester

Earth loop impedance testers for fault loop and protective conductor testing.

0–2000 ΩAcc: ±2% FSIEC 61557

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Voltage Range Check

Megohmmeter received. Available test voltages, resistance ranges, and special functions (DAR, PI) documented.

02

Reference Resistance Connection

High-voltage resistance standard connected to megohmmeter output. Test voltage set to nominal value.

03

Multi-Point Resistance Calibration

Insulation resistance calibrated at 3–5 setpoints per test voltage (e.g., 1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 1 TΩ) against certified resistance standard.

04

Test Voltage Accuracy Verification

Actual output test voltage measured at all nominal settings (100 V, 250 V, 500 V, 1 kV, etc.) against NABL-traceable voltmeter.

05

Error & Uncertainty Calculation

Error at each resistance setpoint documented. Expanded uncertainty (k=2) per GUM. Certificate lists each test voltage and resistance point.

06

NABL Certificate Issue

NABL CC-2480 certificate with resistance data, test voltage, deviations, uncertainty (k=2), IEC 61557-2 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

IEC 61557-2

Insulation Resistance Measurement

IEC 61557-8

Insulation Monitoring Devices

IEEE 43-2013

Motor Winding Insulation Testing

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Megohmmeter and insulation tester certificates accepted by ISO 9001, IEC 60364, and all electrical safety QMS audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Insulation Tester Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Courier pick-up and delivery across Gujarat. Typical 1-day turnaround.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL megohmmeter certificate from Prism has been accepted by ISO 9001, electrical safety, and process industry auditors — no rejections.

NABL CC-2480 — ILAC MRA
IEC 60364, ISO 9001, and electrical safety auditors accept our certificates.
1-Day Turnaround
Megohmmeters calibrated and certified in 1 business day.
Gujarat-Wide Courier
Insured pick-up and delivery from any Gujarat location.
Triple Govt. Authorization
NABL + GPCB + BEE — rare triple accreditation in Gujarat.
70+ Engineers
NABL-certified electrical specialists
1-Day Turnaround
Fast digital certificate delivery
Zero Rejections
Every certificate ISO accepted
All Gujarat
Every GIDC zone covered
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of electrical metrology

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Insulation Tester Calibration Quote

Share the make/model, test voltage, resistance range, and quantity. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.