Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Ammeter
Calibration
NABL Accredited

NABL-accredited calibration for digital and analogue ammeters, CT assemblies, and 4–20 mA current meters. 1 µA to 3000 A. IEC 61010 and IEC 60051. All makes.

±0.01%

Accuracy

1 µA–3000 A

Range

IEC 61010

Standard

IEC 61010 / IEC 60051

Current Measuring Instruments

Ammeter calibration NABL accredited Gujarat electrical

NABL Accredited

CC-2480

NABL CC-2480IEC 61010IEC 60051DC & AC Current1 µA–3000 ACT AssembliesNPL TraceableISO 9001 AcceptedAll GujaratNABL CC-2480IEC 61010IEC 60051DC & AC Current1 µA–3000 ACT AssembliesNPL TraceableISO 9001 AcceptedAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS AMMETER CALIBRATION —

What Is Ammeter Calibration & Why Does It Matter?

Think of a quality lab that relies on an ammeter for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Ammeter calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Ammeters We Calibrate

Digital / Analogue Panel / CT Assembly / Shunt / mA Meter · All Makes · IEC 61010 · NABL accredited

01

Analog Ammeter

Analog moving-iron and moving-coil ammeters for AC/DC current measurement.

0–100 A ACAcc: ±1.5% FSIEC 60051
02

Digital Ammeter

Digital ammeters with LCD/LED display for precise current readings.

0–600 A AC/DCAcc: ±0.5% FSIEC 61010
03

Panel Mount Ammeter

Panel-mounted ammeters for switchboards and distribution boards.

0–2000 A ACAcc: ±1.0% FSIS 1248
04

Microammeter / Milliammeter

Sensitive instruments measuring microampere and milliampere ranges.

0–2000 µA / 0–200 mAAcc: ±0.5% FSIEC 61010
05

DC Ammeter

DC clamp and inline ammeters for battery and solar systems.

0–50 A DCAcc: ±0.5% FSIEC 61010
06

High Current Ammeter

High-range ammeters for industrial motors and power lines.

0–10,000 A ACAcc: ±1.0% FSIEC 60051

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Range Check

Ammeter received. Current range, input type (direct or CT secondary), and AC/DC function documented.

02

Reference Source Setup

NABL-traceable precision current source connected. For CT assemblies, primary current injector set up per IEC 61869.

03

5-Point Calibration

Current calibrated at 5 points spanning the full range: 10%, 25%, 50%, 75%, 100% of rated current. DC and AC calibrated separately.

04

CT Ratio Verification (if applicable)

For CT assemblies: primary current vs secondary reading ratio verified. Ratio error and phase displacement documented per IEC 61869.

05

Error & Uncertainty Calculation

Error at each calibration point. Expanded uncertainty (k=2) per GUM. Results compared to manufacturer specification.

06

NABL Certificate Issue

NABL CC-2480 certificate with current data, deviations, uncertainty (k=2), IEC 61010 / IEC 60051 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

IEC 61010-1

Safety for Measuring Instruments

IEC 60051

Analogue Indicating Instruments

IEC 61869

Instrument Transformers (CT)

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Ammeter certificates accepted by ISO 9001, pharma, IATF 16949, and all process industry QMS audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Ammeter Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

1-day turnaround. Courier pick-up and delivery across Gujarat.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL ammeter certificate from Prism has been accepted by ISO 9001, pharma, and industry audit bodies — no rejections.

NABL CC-2480 — ILAC MRA
ISO 9001 and IATF 16949 auditors worldwide accept our certificates.
1-Day Turnaround
Ammeters calibrated and certified in 1 business day.
Gujarat-Wide Courier
Insured pick-up and delivery from any Gujarat location.
Triple Govt. Authorization
NABL + GPCB + BEE — rare triple accreditation in Gujarat.
70+ Engineers
NABL-certified electrical specialists
1-Day Turnaround
Fast digital certificate delivery
Zero Rejections
Every certificate ISO accepted
All Gujarat
Every GIDC zone covered
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of electrical metrology

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Ammeter Calibration Quote

Share the make/model, current range, and quantity. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.