Micropipette
Calibration
NABL Accredited

NABL-accredited micropipette calibration for all makes and volume ranges. ISO 8655 gravimetric method. 0.1 µL–5000 µL. Pharma GMP & ISO 15189 compliant.

0.1 µL – 5 mL

Range

ISO 8655 Gravimetric

Method

ISO 8655-2 / -6

Standard

ISO 8655-2 / ISO 8655-6

Air-Displacement Micropipette Calibration

Micropipette calibration NABL ISO 8655 Gujarat pharma

NABL Accredited

CC-2480

NABL CC-2480ISO 8655-2ISO 8655-60.1–5000 µLGravimetric MethodPharma GMPISO 15189Eppendorf/Gilson/RaininAll GujaratNABL CC-2480ISO 8655-2ISO 8655-60.1–5000 µLGravimetric MethodPharma GMPISO 15189Eppendorf/Gilson/RaininAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS MICROPIPETTE CALIBRATION —

What Is Micropipette Calibration & Why Does It Matter?

Think of a quality lab that relies on a micropipette for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Micropipette calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Micropipettes We Calibrate

Single-Channel / Multichannel · 0.1 µL–5 mL · All Makes · ISO 8655 Gravimetric · NABL CC-2480

01

Single Channel Micropipette

Single-channel micropipettes for precise µL volume liquid handling.

0.1–1000 µL±0.5% CVISO 8655
02

Multichannel Micropipette

Multichannel micropipettes for parallel liquid dispensing in microplates.

0.5–200 µL (8/12 channel)±1% CVISO 8655
03

Repeat Dispenser Pipette

Repeat dispenser micropipettes for repetitive dispensing of the same volume.

10–10,000 µL±0.5% CVISO 8655
04

Fixed Volume Micropipette

Fixed-volume micropipettes with non-adjustable volume for error-free dispensing.

10–1000 µL (fixed)±0.5% FSISO 8655
05

Auto-Dispensing Micropipette

Auto-dispensing micropipettes with motorized drive for consistent dispensing.

10–10,000 µL±0.3% CVISO 8655
06

Electronic Pipette

Electronic micropipettes with digital display and motorized aspiration.

0.5–1000 µL±0.2% CVISO 8655

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Temperature Stabilisation

Micropipette and ultra-pure water (ISO 3696 Grade 1) stabilised at 20 ± 0.5°C in temperature-controlled lab. Pipette tip type (manufacturer recommended) confirmed before calibration.

02

Visual & Functional Inspection

Pipette inspected for tip seal, shaft condition, volume display, and piston action. Leakage check performed before gravimetric measurement.

03

Gravimetric Calibration (ISO 8655)

Water dispensed into tared weighing vessel on NABL semi-micro balance. Minimum 10 repeat dispenses at each of 3 volume setpoints per ISO 8655. Z-factor applied for temperature correction.

04

Systematic Error (Bias) & Repeatability (CV%)

Mean dispensed volume, systematic error (bias %), and coefficient of variation (CV%) computed for each setpoint. Results compared to ISO 8655-2 maximum permissible error for the nominal volume.

05

Expanded Uncertainty (GUM)

Expanded uncertainty (k=2) calculated per GUM. Contributions: balance standard uncertainty, evaporation correction, Z-factor uncertainty, thermal stability, and repeatability.

06

NABL Certificate Issue

NABL CC-2480 certificate reporting nominal volume, mean dispensed volume, systematic error %, CV%, uncertainty (k=2), ISO 8655 compliance status, and calibration temperature.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 8655-2

Single-channel piston pipettes

ISO 8655-6

Multichannel piston pipettes

ISO 15189

Medical Laboratory Accreditation

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Micropipette certificates accepted by pharma GMP (21 CFR Part 211 / EU GMP), ISO 15189, ISO 9001, and all biomedical and diagnostic laboratory accreditation bodies.

— NON-NABL CALIBRATION —

Non-NABL Micropipette Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Lab or on-site calibration for all micropipettes. 1-day turnaround.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Every NABL micropipette certificate from Prism has been accepted by pharma GMP and ISO 15189 auditors since 2004 — no rejections.

NABL CC-2480 — ILAC MRA
Accepted by pharma GMP, ISO 15189, and ISO 9001 globally.
1-Day Turnaround
Pipette batches calibrated and certified in 1 business day.
On-Site Available
Portable balance for GMP-controlled clean labs.
Triple Govt. Authorization
NABL + GPCB + BEE — rare triple accreditation in Gujarat.
70+ Engineers
NABL-certified volumetric specialists
1-Day Turnaround
Fast digital certificate delivery
Zero Rejections
Every certificate ISO/GMP accepted
All Gujarat
Every GIDC zone covered
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of volumetric metrology

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Micropipette Calibration Quote

Share the make, volume range, and quantity. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.