Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Weight Box
Calibration
NABL Accredited

NABL-accredited calibration for E2, F1, F2, M1, and M2 class weight boxes. 1 mg – 50 kg. OIML R 111. Pharma GMP compliant. All Gujarat.

1 mg – 50 kg

Range

E2 / F1 / F2 / M1 / M2

Classes

OIML R 111

Standard

OIML R 111

Weights of Classes E1 – M3

Weight box calibration NABL OIML R111 Gujarat

NABL Accredited

CC-2480

NABL CC-2480OIML R 111E2 / F1 / F2 / M1 / M21 mg – 50 kgNPL TraceableGUM UncertaintyPharma GMPISO 9001 AcceptedAll GujaratNABL CC-2480OIML R 111E2 / F1 / F2 / M1 / M21 mg – 50 kgNPL TraceableGUM UncertaintyPharma GMPISO 9001 AcceptedAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS WEIGHT BOX CALIBRATION —

What Is Weight Box Calibration & Why Does It Matter?

Think of a quality lab that relies on a weight box for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Weight Box calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Weight Box Classes We Calibrate

E2 / F1 / F2 / M1 / M2 · 1 mg – 50 kg · OIML R 111 · NABL CC-2480

01

Standard Weight Box (Class E1/E2)

Class E1 and E2 weight boxes for highest-accuracy reference calibration.

1 mg–1 kgMPE: Class E1/E2OIML R 111
02

Class F1/F2 Weight Box Set

Class F1 and F2 weight box sets for precision balance calibration.

1 mg–5 kgMPE: Class F1/F2OIML R 111
03

Class M1/M2/M3 Weight Box

Class M1, M2, and M3 weight boxes for industrial weighing calibration.

1 g–20 kgMPE: Class M1/M2/M3OIML R 111
04

OIML Calibration Weight Box

OIML-certified calibration weight boxes for legal-for-trade and reference use.

1 mg–20 kgMPE: OIML ClassOIML R 111
05

Analytical Weight Box (1mg–200g)

Analytical weight boxes covering 1 mg to 200 g range for laboratory use.

1 mg–200 gMPE: Class E2OIML R 111
06

Milligram Weight Box

Milligram weight boxes for micro and semi-micro balance calibration.

1 mg–100 mgMPE: Class E2OIML R 111

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Cleaning

Weight box received. Each weight cleaned with lint-free cloth and handled with tweezers. Weights acclimatised at 20 ± 1°C for 30 minutes before measurement.

02

Visual Inspection

Each weight inspected for surface damage, corrosion, and identification markings. Adjusted cavity verified for F1/E2 class weights.

03

Individual Mass Comparison

Each weight compared against OIML reference masses of one class higher using NABL-calibrated analytical or semi-micro balance. At least 5 readings per weight.

04

Error & Tolerance Check

Measured mass compared to nominal value. Error and standard deviation calculated. Checked against OIML R 111 maximum permissible error for the stated class.

05

Uncertainty Calculation

Expanded uncertainty (k=2) calculated per GUM for each weight in the set. Reference standard uncertainty, repeatability, and resolution all included.

06

NABL Certificate Issue

NABL CC-2480 certificate listing nominal value, measured mass, error, uncertainty (k=2), and OIML R 111 class for each weight in the set.

— STANDARDS & COMPLIANCE —

Backed by International Standards

OIML R 111

Weights of Classes E1–M3

OIML R 76

Non-Automatic Weighing Instruments

ASTM E617

Standard Weights (US)

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Weight box certificates are accepted by pharma GMP (21 CFR Part 211), ISO 9001, IATF 16949, and all process industry QMS bodies.

— NON-NABL CALIBRATION —

Non-NABL Weight Box Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Lab calibration for all weight boxes. 1-day turnaround for most sets.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL weight certificate from Prism has been accepted by pharma GMP, ISO 9001, and IATF 16949 auditors — no rejections.

NABL CC-2480 — ILAC MRA
Certificates accepted by pharma GMP, ISO 9001, and IATF 16949 auditors.
1-Day Turnaround
Most weight sets calibrated and certified in 1 business day.
All Gujarat Coverage
Collection and delivery service available across Gujarat.
Triple Govt. Authorization
NABL + GPCB + BEE — rare triple accreditation in Gujarat.
70+ Engineers
NABL-certified mass metrology specialists
1-Day Turnaround
Fast digital certificate delivery
Zero Rejections
Every certificate ISO/GMP accepted
All Gujarat
Every GIDC zone covered
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of mass metrology

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Weight Box Calibration Quote

Share the class (E2/F1/F2/M1/M2), range, and quantity. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.