Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Differential Pressure
Gauge Calibration
Services

NABL-accredited calibration for Diaphragm Seal, Digital, Remote Seal, HVAC, and High-Range DP Gauges. ISO 5171 / IEC 61298 traceable. Accepted by ISO 9001, GMP, IBR, PESO auditors.

±0.1% FS

Accuracy

0–100 bar DP

Range

ISO 5171

Standard

ISO 5171

DP Gauge Standard

Differential pressure gauge calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 5171ASME B40.100IEC 61298NPL Traceable0–10 mbar to 100 barFilter MonitoringOnsite GujaratNABL CC-2480ISO 5171ASME B40.100IEC 61298NPL Traceable0–10 mbar to 100 barFilter MonitoringOnsite Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS DIFFERENTIAL PRESSURE GAUGE CALIBRATION —

What Is Differential Pressure Gauge Calibration & Why Does It Matter?

Think of a quality lab that relies on a differential pressure gauge for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Differential Pressure Gauge calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

DP Gauges We Calibrate

All 6 types · All makes · 0–10 mbar to 0–100 bar · NABL accredited

01

Diaphragm Seal DP Gauge

Diaphragm seal differential pressure gauges for viscous and corrosive media.

0–40 bar DPAcc: ±1.0% FSEN 837-3
02

Digital Differential Pressure Gauge

Digital DP gauges with high-accuracy electronic sensing.

0–700 bar DPAcc: ±0.1% FSEN 837-3
03

DP Gauge with Remote Seal

DP gauges with remote seal for high-temperature or corrosive process fluids.

0–40 bar DPAcc: ±1.0% FSEN 837-3
04

Low DP Gauge (0–10 mbar)

Low-range DP gauges for cleanroom, HVAC, and filter monitoring applications.

0–10 mbar DPAcc: ±2.0% FSEN 837-3
05

High DP Gauge (0–100 bar)

High-range DP gauges for hydraulic and high-pressure system monitoring.

0–100 bar DPAcc: ±1.0% FSEN 837-3
06

DP Gauge for Cleanroom/HVAC

Differential pressure gauges designed for cleanroom and HVAC duct pressure monitoring.

0–50 Pa to 0–1000 PaAcc: ±2.0% FSEN 837-3

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Tagging

DP gauge received, tagged. Both high and low pressure ports noted. Range, span, and make documented.

02

As-Found 5-Point Check

Reference DP controller applies 0%, 25%, 50%, 75%, 100% FS to high port with low port at reference. As-found readings logged.

03

Zero & Span Adjustment

Zero set with both ports equalized. Span corrected at full scale. Pointer alignment verified.

04

Linearity & Hysteresis

Ascending and descending 5-point pass. Hysteresis checked. Cleanroom DP gauges verified for low-pressure linearity.

05

As-Left Verification

Post-adjustment readings at all 5 points. Expanded uncertainty (k=2) calculated. Pass/fail recorded.

06

NABL Certificate

NABL CC-2480 certificate with as-found/as-left data, uncertainty, ISO 5171/IEC 61298 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 5171

Pressure Gauges (General)

ASME B40.100

Pressure Gauges & Diaphragm Seals

IEC 61298

Process Measurement Instruments

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. DP gauge certificates accepted by ISO 9001, IATF 16949, GMP/FDA, IBR, PESO, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL DP Gauge Calibration Also Available

Routine maintenance calibration without NABL certification — same engineers, same DP reference, lower cost.

Routine plant maintenance calibration
Filter monitoring DP gauge batch calibration
HVAC DP instrument maintenance
Workshop & utility DP gauges
Cost-effective without audit requirement

DP Reference Controller Lab

All calibrations traceable to NPL via DP reference — only certificate type differs.

Faster Turnaround

Non-NABL DP gauge jobs faster — ideal for large bulk batches and routine maintenance.

Cost-Effective

Lower cost than NABL — right for utility DP gauges, non-critical lines, and HVAC maintenance.

Onsite or In-Lab

Portable DP reference to your plant across Gujarat — same team, same quality.

— AREAS WE SERVICE —

Serving All of Gujarat

Engineers carry portable DP reference controllers to your plant. Zero downtime onsite calibration.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL DP gauge certificate issued by Prism has been accepted by ISO, IATF, GMP, IBR, PESO, and GPCB auditors — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Same-Day Urgent Service
Certificates delivered digitally within 24 hours. Same-day for urgent plant shutdowns.
Onsite, No Downtime
Portable DP reference to your plant. No gauge removal, no production loss.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free DP Gauge Calibration Quote

Tell us the DP gauge type, range, quantity, and make. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.