Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Force Gauge &
Load Cell Calibration
Services

NABL-accredited calibration for digital force gauges, load cells, and proving rings from 1 N to 5000 kN. ISO 376 / ASTM E74 traceable. Accepted by IATF 16949 and ISO 9001 auditors.

±0.05%

Accuracy

1 N – 5000 kN

Range

ISO 376

Standard

ISO 376

Force Transducer Standard

Force gauge load cell calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 376ASTM E74NPL Traceable1 N – 5000 kNTension & CompressionClass 0.5 / 1 / 2IATF AcceptedAll GujaratNABL CC-2480ISO 376ASTM E74NPL Traceable1 N – 5000 kNTension & CompressionClass 0.5 / 1 / 2IATF AcceptedAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS FORCE GAUGE CALIBRATION —

What Is Force Gauge Calibration & Why Does It Matter?

Think of a quality lab that relies on a force gauge for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Force Gauge calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Force Gauges & Load Cells We Calibrate

Handheld / Load Cell / Proving Ring · All makes (HBM, Interface, Chatillon, Imada) · ISO 376 · NABL accredited

01

Digital Force Gauge (Push / Pull)

Digital force gauges for push and pull force measurement in QC and assembly.

0–500 N to 0–5000 NAcc: ±0.3% FSISO 376
02

Analog Force Gauge

Analog force gauges with mechanical dial for simple force measurement.

0–100 N to 0–5000 NAcc: ±1% FSISO 376
03

Handheld Force Meter

Handheld force meters for portable force and weight measurement.

0–50 N to 0–500 NAcc: ±0.5% FSISO 376
04

Load Cell (S-Beam, Shear, Canister)

Various load cell types including S-beam, shear beam, and canister load cells.

0.1 N–2000 kNAcc: ±0.1% FSISO 376

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Inspection

Force gauge / load cell received and tagged. Cable, connector, overload protection, and display unit inspected.

02

Zero & Reference Check

Zero balance verified. Reference load check at 20% and 100% of rated capacity using certified deadweight or force standard.

03

5-Point Force Application

Certified forces applied at 20%, 40%, 60%, 80%, and 100% of rated capacity in tension, compression, or both as applicable.

04

Ascending & Descending Series

Three ascending and three descending measurement series per ISO 376. Creep and return-to-zero verified.

05

Classification (Class 0.5–3)

Reproducibility, interpolation error, and zero error calculated. Force gauge classified as Class 0.5, 1, 2, or 3 per ISO 376.

06

NABL Certificate Issue

NABL CC-2480 certificate with force values, classification, uncertainty (k=2), ISO 376 / ASTM E74 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 376

Calibration of Force-Proving Instruments

ASTM E74

Calibration of Force-Measuring Instruments

OIML R60

Load Cell Metrological Regulation

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Force gauge and load cell certificates accepted by IATF 16949, ISO 9001, and all material testing and structural monitoring audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Force Gauge Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Engineers carry certified deadweights and force transfer standards to your facility. Onsite force gauge calibration across Gujarat.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL force certificate issued by Prism has been accepted by IATF 16949, ISO 9001, and material testing audit bodies — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by IATF, ISO, and ASTM audit bodies globally.
Same-Day Urgent Service
Certificates delivered digitally within 24 hours for urgent production or audit needs.
Onsite In-Situ Calibration
Integrated load cells calibrated without removal from machines across Gujarat.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate IATF & ISO accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Force Gauge Calibration Quote

Tell us the gauge type, range, make/model, quantity, and any urgency. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.