Tensile Testing
Machine (UTM)
Calibration

NABL-accredited calibration for hydraulic and electromechanical UTMs from 1 kN to 2000 kN. ISO 7500-1 / ASTM E4 traceable. Accepted by IATF 16949, NADCAP, and ISO 9001 auditors.

±0.5% FS

Accuracy

1–2000 kN

Range

ISO 7500-1

Standard

ISO 7500-1

UTM Calibration Standard

UTM tensile testing machine calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 7500-1ASTM E4NPL Traceable1 kN – 2000 kNClass 0.5 / 1 / 2Onsite GujaratIATF 16949 AcceptedAll MakesNABL CC-2480ISO 7500-1ASTM E4NPL Traceable1 kN – 2000 kNClass 0.5 / 1 / 2Onsite GujaratIATF 16949 AcceptedAll Makes
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS TENSILE TESTING MACHINE CALIBRATION —

What Is Tensile Testing Machine Calibration & Why Does It Matter?

Think of a quality lab that relies on a tensile testing machine for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Tensile Testing Machine calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

UTMs & Testing Machines We Calibrate

All capacities · All makes (Instron, Zwick, Shimadzu, FIE) · ISO 7500-1 · NABL accredited

01

Servo-Hydraulic UTM

Servo-hydraulic universal testing machines for high-load tensile and compression testing.

1–2000 kNAcc: ±1% FSISO 6892
02

Electromechanical UTM

Electromechanical UTMs for precise speed control in material tensile testing.

0.1–600 kNAcc: ±0.5% FSISO 6892
03

Micro / Mini UTM (Benchtop)

Micro/mini benchtop UTMs for small specimens and thin film testing.

0.01–5 kNAcc: ±0.5% FSISO 6892
04

Flexure / Bend Testing Fixture

Flexure and bend testing fixtures for three-point and four-point bending tests.

0.1–500 kNAcc: ±1% FSISO 178

— OUR PROCESS —

Calibration Process — Step by Step

01

Pre-Calibration Inspection

Machine frame, load cell, crosshead, grips, and hydraulic/servo system inspected. Load cell zero checked.

02

Force Standard Application

Certified force transfer standard (deadweight or proving ring) applied at 20%, 40%, 60%, 80%, and 100% of rated capacity.

03

Ascending & Descending Series

Force measurements taken in ascending and descending order. Repeatability and return-to-zero verified per ISO 7500-1.

04

Class Determination

Relative error, repeatability, interpolation error, and zero error calculated. Machine classified as Class 0.5, 1, or 2.

05

Extensometer Verification

If fitted, extensometer calibrated against certified reference extensometer or device per ASTM E83 / ISO 9513.

06

NABL Certificate Issue

NABL CC-2480 certificate with force values, errors, machine class, uncertainty (k=2), ISO 7500-1 / ASTM E4 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 7500-1

Verification of Static Uniaxial Testing Machines

ASTM E4

Force Verification of Testing Machines

ASTM E83

Verification and Classification of Extensometers

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. UTM calibration certificates accepted by IATF 16949, ISO 9001, NADCAP, and all material testing audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Tensile Testing Machine Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Engineers carry certified force standards to your facility. Onsite UTM calibration with no machine downtime.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL UTM certificate issued by Prism has been accepted by IATF 16949, ISO 9001, and NADCAP auditors — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by IATF, ISO, NADCAP auditors internationally.
Same-Day Urgent Service
Certificates delivered digitally within 24 hours for urgent production shutdowns.
Onsite, No Machine Transport
Engineers carry force standards to your facility — no UTM removal required.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate IATF & NADCAP accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free UTM Calibration Quote

Tell us the machine make/model, capacity, type (hydraulic/electromechanical), and quantity. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.