Anesthesia Machine
Calibration
Services

NABL-accredited calibration for anaesthesia machines, flow meters, vaporizers, and gas pressure systems. ISO 80601-2-13 compliant. Accepted by NABH, WHO GMP, and FDA auditors across Gujarat.

ISO 80601-2-13Anesthesia Standard
Range: 0–10 LPMAccuracy: ±2%Standard: ISO 80601-2-13
NABL CC-2480ISO 80601-2-13ISO/IEC 17025:20170–10 LPM Range±2% AccuracyNABH AcceptedWHO GMPOnsite Gujarat4 Anaesthesia Types
0+
Industries Served
0+
Instruments Calibrated
0+
Expert Engineers
0%
Repeat Client Rate

— WHAT IS IT —

What is Anesthesia Machine Calibration?

Anaesthesia machine calibration is the process of verifying and adjusting the flow meters, vaporizers, and gas pressure regulators on an anaesthesia workstation to ensure accurate gas delivery to the patient breathing circuit.

ISO 80601-2-13 and NABH accreditation standards mandate documented periodic calibration of all anaesthesia equipment used in surgical and procedural settings.

Prism's NABL CC-2480 calibration covers flow meter accuracy, vaporizer output concentration, gas supply pressures, breathing circuit leak testing, and safety alarm verification.

Why Calibration Matters

Incorrect gas flow rates can cause patient awareness during surgery
Inaccurate vaporizer output risks anaesthetic overdose or under-dosage
ISO 80601-2-13 mandates documented periodic calibration
NABH and hospital accreditation require NABL-traceable certificates
Breathing circuit leaks can compromise patient ventilation safety

— INSTRUMENTS COVERED —

Anesthesia Equipment We Calibrate

01

Flow Meter Calibration

Gas flow meters on anaesthesia machines calibrated for accuracy of oxygen, nitrous oxide, and air flow rates.

0–10 LPMRes: ±2%ISO 80601-2-13
02

Vaporizer Output Verification

Anaesthetic vaporizer output concentration verified using calibrated gas analysers at multiple dial settings.

0–10 LPMRes: ±2%ISO 80601-2-13
03

Gas Pressure Calibration

Pipeline and cylinder gas supply pressures calibrated for accurate delivery to the patient breathing circuit.

0–10 LPMRes: ±2%ISO 80601-2-13
04

Leak Test & Safety Check

Complete breathing circuit and machine leak test plus safety alarm verification per ISO 80601-2-13.

0–10 LPMRes: ±2%ISO 80601-2-13

— OUR PROCESS —

Calibration Process — Step by Step

01

Intake & Visual Inspection

Anaesthesia machine received and tagged. Physical inspection — vaporizer condition, flow tubes, gas supply connections, and alarm panel documented.

02

Gas Pressure Verification

Pipeline oxygen, nitrous oxide, and air supply pressures measured at machine inlet and verified against specification.

03

Flow Meter Calibration

Flow meter tubes calibrated at 3+ flow rates for each gas using calibrated mass flow references traceable to NPL.

04

Vaporizer Output Test

Vaporizer output concentration measured at 3+ dial settings using calibrated gas analyser. Deviations from dial setting recorded.

05

Leak Test & Alarm Check

Full breathing circuit leak test at 30 cmH₂O. Oxygen failure alarm, hypoxic guard, and pressure alarms all function-tested.

06

NABL Certificate Issued

NABL CC-2480 certificate issued covering flow meter accuracy, vaporizer output, gas pressures, and ISO 80601-2-13 traceability.

— STANDARDS & COMPLIANCE —

Standards We Work To

ISO/IEC 17025
NABL Accreditation Standard
ISO 80601-2-13
Anaesthesia Equipment Standard
ISO 13485
Medical Device QMS
NABH
Hospital Accreditation
WHO GMP
GMP Compliance
FDA 21 CFR
US FDA Compliance
NPL / NIST
Traceable Reference
ISO 9001:2015
Quality Management

— NON-NABL OPTION —

Non-NABL Calibration Available

Not every calibration needs a NABL certificate. For internal quality checks, maintenance records, or large batch instruments, our non-NABL calibration service offers the same technical precision at a lower cost and faster turnaround.

All non-NABL calibrations use the same NPL-traceable reference standards and follow ISO/IEC 17025 methodology — only the certificate header differs.

Traceable References

All non-NABL jobs use the same NPL-traceable references — only the certificate type differs.

Faster Turnaround

Non-NABL jobs completed faster — ideal for urgent maintenance or large bulk batches.

Cost-Effective

Priced lower than NABL — right choice for internal checks and non-audit use cases.

Onsite or In-Lab

Available at our Ahmedabad lab and as onsite service across Gujarat — same team, same quality.

— SERVICE AREAS —

Onsite Calibration Across Gujarat

AhmedabadVadodaraBharuchDahejAnkleshwarSuratRajkotGandhinagarNadiadAnand

— WHY PRISM —

Why Choose Prism Calibration?

NABL CC-2480 — ILAC MRA

Accepted in 100+ countries. Recognized by FDA, GPCB, WHO GMP auditors internationally.

Fast Certificate Delivery

Same-day urgent service available. Certificates delivered digitally within 24 hours.

100% Onsite, No Downtime

Engineers travel to your facility. No instrument removal.

Triple Govt. Authorization

NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.

70+ Engineers

NABL-certified field & lab specialists

Same-Day Service

Urgent certificates when you need them

Zero Rejections

Every certificate WHO GMP & FDA accepted

All Gujarat

Every GIDC zone covered onsite

ILAC MRA

Globally recognized, 100+ countries

Since 2004

20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

— GET IN TOUCH —

Request a Calibration Quote

Fill in the form and our team will contact you within 2 business hours with pricing and availability for onsite or in-lab anaesthesia machine calibration.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445
WhatsApp Us Now

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.