— WHAT IS ESU CALIBRATION —
In the operating theatre, an electrosurgical unit set to 50W that delivers 80W can cause unintended burns, while one that delivers only 25W fails to cut or coagulate effectively. The accuracy of ESU output power is directly tied to patient safety — yet these devices are rarely tested between installations and annual biomedical maintenance checks.
Electrosurgical analyser calibration measures actual cutting and coagulation output power using calibrated load analysers, verifies RF leakage current is within safe limits per IEC 60601-2-2, and checks all waveform modes. The NABL certificate produced is required by NABH, JCI, and FDA biomedical inspectors — and demonstrates that your surgical equipment operates safely and accurately.
Measure
Power output measured at multiple settings into 200Ω and 500Ω calibrated test loads.
Test
RF leakage current, waveforms, and patient return electrode alarm verified per IEC 60601-2-2.
Certify
NABL CC-2480 certificate issued — accepted by NABH, WHO GMP, and FDA biomedical auditors.
— INSTRUMENTS COVERED —
ESU analysers, RF leakage testers, output testers, and patient return electrode testers — all calibrated per IEC 60601-2-2.
Electrosurgical unit analysers verifying cutting and coagulation power output accuracy across all waveform modes.
High-frequency leakage current measurement instruments calibrated for patient and chassis leakage per IEC 60601-2-2.
Dedicated ESU output power testers for verifying monopolar and bipolar output accuracy into calibrated test loads.
REM / neutral electrode contact quality monitors calibrated for impedance threshold accuracy and alarm function.
— OUR PROCESS —
ESU received, tagged, and visually inspected — cable integrity, footswitch function, panel controls, and alarm system documented.
RF leakage current measured at patient connection and chassis in monopolar and bipolar modes against IEC 60601-2-2 limits.
Cutting and coagulation output power measured at 5+ settings using calibrated ESU analyser into 200Ω and 500Ω test loads.
Cut, blend, and coagulation waveforms verified for peak voltage and duty cycle. All modes tested and deviations recorded.
Post-adjustment power output re-measured across all calibration points. Uncertainty calculated per ISO/IEC 17025.
NABL CC-2480 certificate issued with power output data, leakage current, waveform results, and IEC 60601-2-2 traceability.
— STANDARDS & COMPLIANCE —
Every ESU calibration follows IEC 60601-2-2 with full traceability to NPL national electrical standards. Our certificates satisfy NABH, WHO GMP, FDA, and all biomedical engineering audit requirements.
ISO/IEC 17025
NABL Accreditation Standard
IEC 60601-2-2
Electrosurgical Equipment
IEC 60601-1
Medical Equipment Safety
ISO 13485
Medical Device QMS
NABH
Hospital Accreditation
WHO GMP
GMP Compliance
NPL / NIST
Traceable Reference
ISO 9001:2015
Quality Management
Prism holds NABL CC-2480 under ISO/IEC 17025:2017, recognized under the ILAC MRA agreement. Our biomedical calibration certificates are valid for WHO GMP, FDA, NABH, and all audit purposes.
— NON-NABL CALIBRATION —
For routine maintenance, bulk calibration, or facilities not needing NABL certification — Prism offers cost-effective non-NABL calibration with the same trained engineers and traceable references.
All non-NABL jobs use the same NPL-traceable references — only the certificate type differs.
Non-NABL jobs completed faster — ideal for urgent maintenance or large bulk batches.
Priced lower than NABL — right choice for internal checks and non-audit use cases.
Available at our Ahmedabad lab and as onsite service across Gujarat — same team, same quality.
— AREAS WE SERVICE —
NABL-certified engineers travel to your facility across Gujarat — hospital, pharma, or laboratory onsite service.
Why Choose Prism
Since 2004, every NABL biomedical certificate issued by Prism has been accepted by WHO GMP, FDA, NABH, and ISO auditors — no rejections, no rework.
— FAQ —
Get In Touch
Tell us what you need calibrated and whether you need onsite or in-lab service. We respond within 2 business hours.
— FROM OUR BLOG —
NABL Accreditation Disclaimer
Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.