Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Brinell Hardness
Tester Calibration
Services

NABL-accredited calibration for manual, digital, and portable Brinell hardness testers. ISO 6506 / ASTM E10 traceable. Accepted by ISO 9001, IATF 16949 and foundry audit bodies.

±3 HBW

Accuracy

HBW 8–650

Range

ISO 6506

Standard

ISO 6506

Brinell Hardness Standard

Brinell hardness tester calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 6506ASTM E10NPL TraceableHBW 8–650Foundry & ForgingReference BlocksISO 9001 AcceptedAll GujaratNABL CC-2480ISO 6506ASTM E10NPL TraceableHBW 8–650Foundry & ForgingReference BlocksISO 9001 AcceptedAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS BRINELL HARDNESS TESTER CALIBRATION —

What Is Brinell Hardness Tester Calibration & Why Does It Matter?

Think of a quality lab that relies on a brinell hardness tester for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Brinell Hardness Tester calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Brinell Testers We Calibrate

All loads · All makes (Wilson, Mitutoyo, Zwick, Innovatest) · ISO 6506 · NABL accredited

01

Manual Brinell Hardness Tester

Manual Brinell hardness testers for heavy industrial components and castings.

HBW 100–650Acc: ±3 HBWISO 6506
02

Digital Brinell Hardness Tester

Digital Brinell hardness testers with optical measurement and auto-calculation.

HBW 50–650Acc: ±1 HBWISO 6506
03

Portable Brinell Hardness Tester

Portable Brinell hardness testers for in-situ testing of large components.

HBW 100–650Acc: ±3 HBWISO 6506
04

Brinell Reference Blocks

Certified Brinell reference blocks for tester calibration and verification.

HBW 100–400 (certified)Acc: ±1 HBW (certified)ISO 6506

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Inspection

Tester received, tagged. Ball indenter, anvil, load mechanism, and optical reading system inspected for wear.

02

Reference Block Check

NPL-traceable Brinell reference blocks used to measure as-found deviation at two hardness levels.

03

Load Verification

Applied loads (187.5, 750, 3000 kgf etc.) measured with certified load cell. Deviations corrected per ISO 6506-2.

04

Optical System Calibration

Measurement microscope or digital reader calibrated using certified stage micrometer to verify indentation diameter accuracy.

05

As-Left Verification

Post-adjustment readings on reference blocks at two hardness levels. Repeatability calculated from 3 consecutive indentations.

06

NABL Certificate Issue

NABL CC-2480 certificate issued with as-found/as-left data, expanded uncertainty (k=2), ISO 6506 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 6506-1

Brinell Hardness Test Method

ISO 6506-2

Verification of Testing Machines

ASTM E10

Brinell Hardness of Metallic Materials

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Brinell hardness certificates accepted by ISO 9001, IATF 16949, and all foundry/casting quality audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Brinell Calibration Also Available

For routine plant maintenance or workshops not requiring NABL certification — same engineers, same reference blocks, lower cost.

Routine foundry maintenance calibration
Incoming material inspection testers
Bulk calibration for workshop equipment
Non-critical production floor testers
Cost-effective for projects without audit need

NPL-Traceable Reference Blocks

All calibrations use NPL-traceable Brinell reference blocks — only the certificate type differs.

Fast Turnaround

Non-NABL Brinell jobs completed faster — ideal for large batch foundry maintenance.

Cost-Effective

Lower cost than NABL — suited for workshop testers and non-critical material verification.

Onsite or In-Lab

Portable verification tools to your foundry across Gujarat — same specialist team.

— AREAS WE SERVICE —

Serving All of Gujarat

Engineers visit your foundry or casting facility. Onsite Brinell tester calibration with minimal downtime.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL hardness certificate issued by Prism has been accepted by ISO 9001, IATF 16949, and foundry audit bodies — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by ISO and IATF auditors internationally.
Same-Day Urgent Service
Certificates delivered digitally within 24 hours for urgent production requirements.
Onsite Foundry Service
Engineers visit large foundry equipment. No tester transport required.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Brinell Tester Calibration Quote

Tell us the tester make/model, load, quantity, and any urgency. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.