NABL Accredited · CC-2480 · Est. 2004
Gujarat's most trusted NABL-accredited hardness calibration — Rockwell, Brinell, Vickers, Micro Vickers, Knoop, Shore durometers, portable testers, and reference hardness blocks. NABL certificate CC-2480. Onsite across Gujarat.

Rockwell Hardness Tester

Portable Hardness Tester
Shore A Durometer
NABL Accredited
CC-2480
ISO 6508
Hardness Standard
— WHAT IS HARDNESS TESTER CALIBRATION —
Hardness tester calibration is the process of verifying the indicated hardness values of a Rockwell, Brinell, Vickers, or Shore durometer against NPL/NIST-traceable certified reference test blocks at the applicable loads and scales per ISO 6508, ISO 6506, ISO 6507, or ISO 868.
Two critical states are documented: As-Found (pre-calibration deviation from reference block value) and As-Left (post-adjustment accuracy). Repeatability and reproducibility at each scale are calculated and documented.
Prism Calibration Centre performs all hardness tester calibration under NABL accreditation CC-2480 (ISO/IEC 17025:2017). Certificates accepted by ISO 9001, ISO/TS 16949, BIS, and quality auditors across Gujarat and India.
Hardness Scales Calibrated
HRC
Rockwell
ISO 6508
HV
Vickers
ISO 6507
HBW
Brinell
ISO 6506
Shore A/D · Micro Vickers · Knoop · Leeb/UCI — all covered
Rockwell
HRC/HRB/HRA
Reference block comparison per ISO 6508 with repeatability
Vickers/Brinell
ISO 6507/6506
Optical measurement with certified reference blocks
NABL Cert
CC-2480
Certificate with NPL traceability accepted globally
Multi-Point Calibration Verification
ISO 6508/6506/6507Low
Soft Scale
Mid
Medium
High
Hard Scale
Repeatability & reproducibility per ISO 6508/6506/6507 · NABL CC-2480
— WHAT YOU GET —
Comprehensive hardness tester calibration with full NPL traceability and NABL certification.
Engineer arrives with NPL-traceable certified reference blocks for Rockwell, Vickers, Brinell, and Shore calibration.
No DowntimeEach tester calibrated at low, mid, and high hardness reference points per ISO 6508/6506/6507 for all applicable scales.
Full RangePre and post calibration readings at all test points. Repeatability calculated at each scale. Complete ISO documentation.
ISO 6508/6506/6507NABL certificate with NPL traceability, expanded uncertainty, as-found/as-left data. Valid for ISO 9001 and quality audits.
Digital DeliveryISO 9001 audit tomorrow? Same-day hardness tester calibration and certificate across Gujarat.
Urgent AvailableRockwell, Brinell, Vickers, and Shore reference test blocks calibrated against NPL-traceable master blocks. NABL certified.
All Block TypesPortable rebound (Leeb) and UCI hardness testers calibrated against certified reference blocks with NABL certificate.
Portable TypesScheduled hardness tester calibration program with reminders and priority service for all your instruments.
Planned MaintenanceOnsite Across Gujarat · NABL CC-2480
Onsite service · Same-day urgent · NABL certificate within 24 hours
— INSTRUMENTS COVERED —
40+ hardness instrument types across 8 categories — all makes, all scales, NABL accredited.
Rockwell
4 instrument types
Brinell
4 instrument types
Portable Hardness Tester
4 instrument types
Shore A
4 instrument types
Surface Roughness
4 instrument types
Don't see your tester? We calibrate 200+ instrument types across all major brands.
— OUR PROCESS —
Every hardness calibration follows our documented ISO 6508/6506/6507 procedure — traceable, repeatable, auditable.
Hardness tester received and tagged. Type (Rockwell, Brinell, Vickers), scale, load range, make, model, serial noted. Pre-calibration condition documented.
Indentations made on NABL-traceable certified reference test blocks at defined loads. As-found hardness values recorded at the required number of impressions per ISO 6508/6506/6507.
Measured hardness values compared to NPL/NIST-traceable certified reference block values. Error and repeatability calculated per applicable ISO standard.
Machine adjustments made where manufacturer permits. Indentor geometry and load verified. Correction tables issued for machines with non-adjustable readings.
Post-adjustment readings verified against reference blocks at all required scales and loads. Expanded uncertainty calculated per ISO/IEC 17025. Pass/fail recorded.
NABL CC-2480 certificate with as-found/as-left data, expanded uncertainty, ISO 6508/6506/6507 traceability. Digital delivery within 24 hours.
Industry Applications
Calibrated hardness testers are essential for material quality verification across metals, polymers, and engineered components.
Rockwell and Brinell hardness testers for steel, alloy, and cast iron quality verification per IS/ISO standards.
Know MoreVickers and Rockwell hardness calibration for hardened components, gears, shafts, and treated surfaces.
Know MoreHardness testing of chemical plant components, vessel materials, and corrosion-resistant alloys.
Know MoreMaterial hardness verification for turbine blades, defence components, and pressure vessel materials.
Know MoreShore A/D durometer calibration for rubber, silicone, and polymer hardness measurement in production.
Know MoreMicro Vickers and Knoop hardness for thin coatings, case depth verification, and aerospace materials.
Know MoreHardness tester calibration for cutting tool hardness verification and heat treatment quality control.
Know MoreAll hardness scales and portable testers calibrated for materials research, incoming inspection, and quality labs.
Know MoreWhy Choose Prism
Since 2004, every NABL hardness tester calibration certificate issued by Prism has been accepted by ISO 9001 and quality auditors — no rejections, no rework, no compliance gaps.
— STANDARDS & COMPLIANCE —
Every hardness calibration at Prism follows documented ISO 6508, 6506, 6507, and ISO 868 procedures — accepted by ISO 9001, BIS, and global quality auditors.
ISO 6508
Rockwell Hardness Calibration
ISO 6506
Brinell Hardness Calibration
ISO 6507
Vickers Hardness Calibration
ISO 4545
Knoop Microhardness
ISO/IEC 17025
NABL Accreditation Standard
ISO 868
Shore Durometer Standard
ISO 9001:2015
Quality Management System
ASTM E18 / E10
Rockwell / Brinell (ASTM)
Prism holds NABL accreditation CC-2480 under ISO/IEC 17025:2017, recognized under the ILAC MRA agreement. Our hardness tester calibration certificates carry the same legal weight as any NABL lab worldwide — valid for ISO 9001, BIS, and international audits.
8+
Hardness Scales
40+
Hardness Instrument Types
Onsite Coverage
NABL-certified engineers travel to your facility with certified reference blocks — no instrument removal, zero production downtime.
All under one NABL-accredited roof — CC-2480
Pressure Calibration
Gauges, transmitters, dead weight testers.
Temperature Calibration
Thermocouples, RTDs, data loggers.
Electrical Calibration
Multimeters, clamp meters, power analyzers.
HART Calibration
Smart HART transmitters, sensor & output trim.
Flow & Mass Calibration
Flow meters, weighing balances, pipettes.
UTM & Torque
Force gauges, load cells, torque wrenches.
Biomedical Calibration
Autoclaves, incubators, pH meters.
All Services
View complete calibration & testing catalog.
— Our Clients —


— CLIENT VOICES —
Prism calibrates all our Rockwell and Brinell hardness testers annually under NABL. Certificates accepted in our ISO 9001 audits without any deficiencies. Professional, accurate, fast.
Our Vickers hardness testers and reference blocks are calibrated by Prism every year. NABL-accredited with full ISO 6506 traceability. Same-day certificate delivery. Excellent service.
Hardness tester calibration for our R&D lab — Rockwell, Vickers, and Shore durometer all done by Prism. NABL certificates with as-found/as-left data, accepted in all our quality audits.
Prism calibrates all our Rockwell and Brinell hardness testers annually under NABL. Certificates accepted in our ISO 9001 audits without any deficiencies. Professional, accurate, fast.
Our Vickers hardness testers and reference blocks are calibrated by Prism every year. NABL-accredited with full ISO 6506 traceability. Same-day certificate delivery. Excellent service.
Hardness tester calibration for our R&D lab — Rockwell, Vickers, and Shore durometer all done by Prism. NABL certificates with as-found/as-left data, accepted in all our quality audits.
Prism calibrates all our Rockwell and Brinell hardness testers annually under NABL. Certificates accepted in our ISO 9001 audits without any deficiencies. Professional, accurate, fast.
Our Vickers hardness testers and reference blocks are calibrated by Prism every year. NABL-accredited with full ISO 6506 traceability. Same-day certificate delivery. Excellent service.
Hardness tester calibration for our R&D lab — Rockwell, Vickers, and Shore durometer all done by Prism. NABL certificates with as-found/as-left data, accepted in all our quality audits.
Get In Touch
Describe your requirement — Rockwell, Brinell, Vickers, Shore, or onsite hardness calibration. Our team responds within 2 business hours.
— FAQ —
Everything about hardness tester calibration, NABL compliance, and our services.
Call or WhatsApp — we reply within the hour. Onsite or in-lab, NABL certificate guaranteed.
Prism Calibration Centre · F 101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad, Gujarat 382445
— FROM OUR BLOG —
Surface roughness (Ra, Rz) is a critical quality parameter in precision machining, sealing surfaces, and coating adhesion. NABL-certified roughness tester calibration ensures accurate surface texture measurements.
Read MoreHardness testing is fundamental to material qualification in automotive, tooling, and steel industries. NABL-certified hardness tester calibration ensures traceable, accurate hardness values.
Read MoreGujarat's steel and fabrication sector — from mini steel mills to pressure vessel manufacturers — requires NABL-certified calibration for BIS material testing, ISO 9001, and structural safety compliance.
Read MoreNABL Accreditation Disclaimer
Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.