Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Micrometer
Calibration
Services

NABL-accredited calibration for all micrometer types — Outside, Inside, Depth, Bench & Disc Micrometers. ISO 3611 traceable, ±0.5 µm uncertainty, accepted by ISO 9001, IATF 16949.

±0.5 µm

Uncertainty

0–500 mm

Range

ISO 3611

Standard

ISO 3611

Micrometer Standard

Micrometer calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 3611NPL Traceable±0.5 µm UncertaintyISO 9001 AcceptedIATF 169495 Micrometer TypesOnsite GujaratNABL CC-2480ISO 3611NPL Traceable±0.5 µm UncertaintyISO 9001 AcceptedIATF 169495 Micrometer TypesOnsite Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS MICROMETER CALIBRATION —

What Is Micrometer Calibration & Why Does It Matter?

A micrometer that reads 0.01mm high on every shaft it measures will pass hundreds of out-of-tolerance parts before anyone notices. Micrometer calibration catches zero drift, anvil wear, and spindle errors — and documents them in an NABL certificate accepted by every quality auditor.

Check

Measured against NPL-traceable Grade-A gauge blocks at 5+ points across full range. As-found data recorded.

Correct

Zero adjustment, anvil flatness check, thimble backlash. Correction table issued if needed.

Certify

NABL CC-2480 certificate with as-found/as-left data — accepted by ISO 9001 & IATF.

— INSTRUMENTS COVERED —

Micrometers We Calibrate

All 5 micrometer types · All makes (Mitutoyo, Baker, Insize, Mahr, Starrett) · NABL accredited

01

Outside Micrometer (0–500mm)

Outside micrometers for precision external diameter and thickness measurement.

0–500 mmRes: ±0.001 mmISO 3611
02

Inside Micrometer

Inside micrometers for precise internal bore and groove measurement.

5–300 mmRes: ±0.002 mmISO 3611
03

Depth Micrometer

Depth micrometers for measuring depths of slots, holes, and steps.

0–300 mmRes: ±0.001 mmISO 3611
04

Bench Micrometer

Bench micrometers for high-accuracy dimensional measurement on a stand.

0–300 mmRes: ±0.0005 mmISO 3611
05

Disc Micrometer

Disc micrometers with disc-type anvil for measuring grooves and recesses.

0–100 mmRes: ±0.001 mmISO 3611

— OUR PROCESS —

Calibration Process — Step by Step

01

Intake & Tagging

Micrometer received, tagged, incoming condition documented — spindle condition, thimble action, zero check.

02

Zero & Cleaning

Spindle and anvil cleaned, zero error noted (as-found). Thimble movement and ratchet/friction stop checked.

03

As-Found Measurement

Measured against NPL-traceable Grade-A gauge blocks at 5+ points. All deviations recorded.

04

Adjustment

Zero adjustment performed. Correction table issued for fixed-reading instruments.

05

As-Left Verification

Post-adjustment readings verified at all calibration points. Uncertainty calculated per ISO/IEC 17025.

06

NABL Certificate

NABL CC-2480 certificate with as-found/as-left data, uncertainty (k=2), ISO 3611 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

Every micrometer calibration follows documented ISO 3611 and NPL procedures — accepted by ISO 9001, IATF 16949, BIS, and all audit bodies.

ISO 3611

Micrometers for External Measurement

IS 2092

Micrometers (Indian Standard)

ISO/IEC 17025

NABL Accreditation Standard

VDI/VDE 2617

Gauges & Measuring Instruments

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017, recognized under the ILAC MRA agreement. Our micrometer calibration certificates are valid for ISO 9001, IATF 16949, BIS, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL Micrometer Calibration Also Available

For routine maintenance, bulk calibration, or workshops not needing NABL certification — Prism offers cost-effective non-NABL micrometer calibration with the same trained engineers and traceable references.

Internal maintenance & routine checks
Pre-delivery and incoming inspection
Bulk calibration for non-critical micrometers
R&D, prototype & workshop environments
Cost-effective for projects without audit requirements

Traceable References

All non-NABL jobs use the same NPL-traceable gauge blocks — only the certificate type differs.

Faster Turnaround

Non-NABL micrometer jobs completed faster — ideal for urgent maintenance or large bulk batches.

Cost-Effective

Priced lower than NABL — right choice for internal checks and non-audit use cases.

Onsite or In-Lab

Available at our Ahmedabad lab and as onsite service across Gujarat — same team, same quality.

— AREAS WE SERVICE —

Serving All of Gujarat

NABL-certified engineers travel to your facility with portable gauge block sets — calibrate 50+ micrometers per day onsite, zero downtime.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL micrometer certificate issued by Prism has been accepted by ISO, IATF, BIS, FDA, and GPCB auditors — no rejections, no rework.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Fast Certificate Delivery
Same-day urgent service available. Certificates delivered digitally within 24 hours.
100% Onsite, No Downtime
Engineers travel to your facility with gauge block sets. No instrument removal.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Micrometer Calibration Quote

Tell us how many micrometers you need calibrated, the types and ranges, and whether you need onsite or in-lab service. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.