Chamber
Temperature Mapping

NABL-accredited temperature mapping for lab ovens, pharma stability chambers, cold rooms, and ULT freezers. ICH Q1A(R2), WHO TRS 961, and IEC 60068. Pharma, vaccine, and cGMP accepted.

±0.2°C

Accuracy

-80–300°C

Range

ICH Q1A

Standard

ICH Q1A(R2) / WHO TRS 961

Pharma Stability Mapping

Stability chamber temperature mapping ICH WHO pharma Gujarat

NABL Accredited

CC-2480

NABL CC-2480ICH Q1A(R2)WHO TRS 961IEC 60068Pharma MappingCold RoomStability ChamberThermal MappingAll GujaratNABL CC-2480ICH Q1A(R2)WHO TRS 961IEC 60068Pharma MappingCold RoomStability ChamberThermal MappingAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS OVEN & STABILITY CHAMBER CALIBRATION —

What Is Oven & Stability Chamber Calibration & Why Does It Matter?

Think of a quality lab that relies on an oven & stability chamber for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Oven & Stability Chamber calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Ovens & Chambers We Map

Lab Oven / Stability Chamber / Cold Room / ULT Freezer / Environmental Chamber · All Makes · ICH / WHO

01

Laboratory Oven

Laboratory ovens for drying, sterilization, and high-temperature testing.

Ambient to 300°CAcc: ±1°CIEC 60068
02

BOD Incubator

BOD incubators for biological oxygen demand testing at controlled temperatures.

5°C to 60°CAcc: ±0.5°CISO 8655
03

Refrigerator / Cold Chamber

Refrigerators and cold chambers for cold storage and cold temperature calibration.

-86°C to +10°CAcc: ±1°CIEC 60068
04

Stability Chamber

Stability chambers for pharmaceutical ICH stability testing at controlled T and RH.

+5°C to +60°C / 40–90% RHAcc: ±0.5°C / ±2% RHICH Q1A
05

Environmental Test Chamber

Environmental test chambers for combined temperature and humidity testing.

-70°C to +180°C / 10–98% RHAcc: ±0.5°C / ±2% RHIEC 60068
06

Walk-in Cold Room

Walk-in cold rooms for large-scale cold storage and temperature uniformity testing.

-30°C to +10°CAcc: ±1°CIEC 60068

— OUR PROCESS —

Temperature Mapping Process — Step by Step

01

Pre-Mapping Consultation

Chamber setpoint, chamber size, regulatory requirement (ICH, WHO, NADCAP, ISO) and number of sensor positions agreed. Sensor placement diagram prepared.

02

Sensor Placement

Calibrated PT100 or TC sensors placed at specified positions (corners, centre, near door, near fan). Sensor positions photographed and documented.

03

Setpoint Stabilization

Chamber allowed to stabilize at setpoint for minimum 60 minutes. Stability confirmed via reference data logger before mapping window starts.

04

Spatial Mapping

Simultaneous temperature data collected from all sensor positions over minimum 4 hours. Hot spot, cold spot, maximum spread documented.

05

Worst-Case Analysis

Mean kinetic temperature (MKT) or min/max analysis performed per applicable standard. Worst-case sensor position identified for ongoing monitoring probe placement.

06

NABL Certificate & Mapping Report Issue

NABL CC-2480 calibration certificate with sensor data, layout map, uniformity analysis, and qualification summary issued.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ICH Q1A(R2)

Pharma Stability Testing Guidelines

WHO TRS 961

Vaccine & Cold Chain Storage

IEC 60068-2-1/2

Environmental Stress Testing

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Oven and stability chamber mapping reports accepted by CDSCO, USFDA, MHRA, WHO-cGMP, NABL-accredited labs, and ISO 9001 audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Oven & Stability Chamber Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Onsite temperature mapping across all pharma, food, and R&D clusters in Gujarat. Engineers carry calibrated sensor arrays.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL mapping report from Prism has been accepted by pharma regulatory bodies and QMS auditors — no rejections.

NABL CC-2480 — ILAC MRA
CDSCO, USFDA, MHRA, and WHO-cGMP auditors accept our mapping reports.
Rapid Onsite Service
Temperature mapping surveys scheduled within 2–5 business days across Gujarat.
Onsite Mapping Service
Full onsite chamber and oven mapping at your facility anywhere in Gujarat.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified stability mapping experts
Rapid Scheduling
Surveys within 2–5 business days
Zero Rejections
Every report pharma & regulatory accepted
All Gujarat
Every pharma and GIDC zone covered
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of thermal mapping service

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Stability Chamber Mapping Quote

Share chamber type, setpoint, size, and regulatory standard needed. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.