Prism Calibration Centre
Equipment Guide

Dimensional Calibration Services in Ahmedabad — NABL | Prism

PK
Er. Parthiv Kinariwala · MD, Prism Calibration Centre
28 April 2026 7 min read
NABL CC-2480 ISO/IEC 17025:2017 20+ Years Experience GPCB Authorised ILAC MRA Recognised

Quick Answer

Prism Calibration Centre (NABL CC-2480) provides NABL-certified dimensional calibration services in Ahmedabad, covering vernier calipers (0–3000 mm), micrometers (0–500 mm), dial gauges (0.001 mm), height gauges, bore gauges, surface roughness testers, and CMM qualification probes.

Key Takeaways

  • Dimensional calibration per ISO 13225, ISO 3611, ISO 463, and VDI/VDE 2617 standards.
  • Resolution down to 0.0001 mm (0.1 µm) using Zeiss CMM and surface plate reference.
  • Gauge block sets (Grade K, Grade 00, Grade 0, Grade 1) available as reference standards.
  • Temperature-controlled calibration room at 20°C ± 0.5°C for dimensional stability.
  • Certificate includes measurement result, expanded uncertainty, and gauge R&R data on request.

Dimensional Instruments Calibrated at Prism

  • Vernier calipers (inside/outside/depth/height) — 0 to 3000 mm
  • Outside micrometers (standard and blade) — 0 to 500 mm
  • Inside micrometers and bore gauges
  • Depth micrometers and depth vernier calipers
  • Dial indicators / dial gauges (0.001 mm resolution)
  • Digital indicators (0.0001 mm resolution)
  • Height gauges (manual and digital) — 0 to 600 mm
  • Feeler gauges and thickness gauges
  • Plug gauges, ring gauges, snap gauges
  • Angle gauges and sine bars
  • Surface roughness testers (Ra, Rz, Rmax)
  • CMM (Coordinate Measuring Machine) probe qualification
  • Radius gauges and profile gauges

Dimensional Calibration for Automotive in Gujarat

Gujarat's automotive sector — Tata Motors (Sanand), Maruti Suzuki supply chain, Honda, Hero, and 1000+ Tier 1–2 component suppliers — demands dimensional calibration with gauge R&R (repeatability and reproducibility) studies to IATF 16949 requirements. Prism provides NABL-certified dimensional calibration with measurement uncertainty values that support gauge R&R analysis.

Temperature-Controlled Dimensional Calibration Room

Dimensional measurements are highly sensitive to temperature — steel expands 11.7 µm per metre per °C. All dimensional calibrations at Prism are performed in our temperature-controlled calibration room maintained at 20°C ± 0.5°C (as per ISO 1 — the international standard reference temperature for dimensional measurement). This ensures your calibration results are directly comparable to manufacturer specifications.

Frequently Asked Questions

What is the smallest resolution Prism can calibrate for dimensional instruments?

Prism calibrates instruments with resolution down to 0.0001 mm (0.1 µm) using reference gauge blocks (Grade 00) and a Zeiss Contura CMM with probe qualification.

Can Prism calibrate large-range vernier calipers up to 2000 mm?

Yes. Prism calibrates vernier calipers, digital calipers, and height gauges up to 3000 mm range using calibrated steel rules and reference length standards.

Does Prism calibrate CMM machines?

Prism calibrates CMM probe systems (qualification spheres, styli) and provides reference gauge blocks for CMM performance verification. Full CMM volumetric performance verification is done by CMM OEM service engineers.

Is dimensional calibration required for IATF 16949?

Yes. IATF 16949 Clause 7.1.5.3 (MSA) requires all gauging instruments in production to be calibrated by NABL-accredited labs, with measurement uncertainty values for gauge R&R studies.

How does Prism handle large plug gauges and ring gauges?

Large plug gauges (up to 100 mm diameter) and ring gauges are calibrated using a calibrated CMM or precision bench micrometer. Gauges outside Prism's scope are calibrated through accredited partner labs.

Written by

PK

Er. Parthiv Kinariwala

Managing Director · Prism Calibration Centre · NABL CC-2480 · Ahmedabad

Er. Parthiv Kinariwala founded Prism Calibration Centre in 2004 and has over 20 years of hands-on experience in calibration engineering, NABL accreditation, and industrial compliance. His team performs 10,000+ calibrations annually from the Vatva GIDC laboratory, serving 5000+ industries across Gujarat.

NABL CC-2480 SignatoryISO/IEC 17025 ExpertGPCB AuthorisedBEE Energy AuditorILAC MRA Member

Prism Calibration Centre — Vatva GIDC, Ahmedabad

Prism Calibration Centre

F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Near Jasoda Nagar Cross Road, Ahmedabad382445, Gujarat, India

Phone: +91 98245 26444

Email: info@prismcalibration.com

NABL: CC-2480 · ISO/IEC 17025:2017

Hours: Mon–Sat, 9:00 AM – 7:00 PM